What “lab-grade” is actually claiming

Every EEG vendor says lab-quality. Here is the specific, checkable claim behind the phrase — and the parts of it we refuse to make.

What “lab-grade” is actually claiming

“Lab-grade” is a marketing phrase that has been worn smooth by overuse. It can mean anything from a genuinely low noise floor to a headset that looks expensive. So it is worth saying precisely what we mean by it, and — more usefully — what we do not.

It is a claim about acquisition

When we say lab-grade, we are talking about four properties of the recording, all of them measurable, all of them published:

  • Channel count. Eight active electrodes, with a defined montage rather than a vague

“frontal” position.

  • Sample rate. 250 Hz, with a 0.02–125 Hz bandwidth — wide enough to keep the slow

drift and the fast activity in one file.

  • Resolution. A 24-bit ADC, so a small signal does not disappear into quantisation.
  • Noise floor. 0.16 µVrms input-referred on the Full Kit. This is the number that

separates an instrument from a toy, and it is the one we are most often asked to prove.

None of those four are opinions. You can check them against the recording.

What “lab-grade” is actually claiming — illustration

It is not a claim about interpretation

This is the part the industry is vague about. A low noise floor tells you the signal is clean. It does not tell you that a classifier's output means what the marketing copy says it means. “Accuracy” in BCI is a property of a model on a task, not of a headset, and conflating the two is how neurotech gets a reputation.

We publish acquisition specifications. For interpretation, we give you the raw stream and the SDK, so the claim can be checked instead of trusted.

Why the raw data stays open

If the value of the device is the quality of the acquisition, then restricting the data is self-defeating. A researcher who cannot audit the signal cannot cite it. A developer who cannot feed their own pipeline cannot build on it. Locking the data behind an API would make the hardware worse at the only thing it is good at.

So: full rate, unprocessed, exported as CSV, EDF or JSON, with artefact labels in the stream rather than silent deletions. Nothing is filtered before you see it.

What “lab-grade” is actually claiming — illustration

The deliberate silences

There are things we do not publish, and we would rather list them than let them be guessed at: device weight, dimensions, enclosure material, battery capacity, session runtime, electrode impedance, filter design, warranty. When those are measured against production hardware, they will appear here with the same specificity as the numbers above.

And the boundary we will not cross: BROADMIND is not a medical device. It does not diagnose, treat, cure or prevent anything, and nothing it reports is medical advice. That sentence is in the footer of every page for a reason.


BROADMIND builds non-invasive EEG hardware with unrestricted raw-data access and an open SDK. Specifications are published in full on the product page.